Helena at the Metropole Zličín shopping mall - 232 days and what we learned

Continuous operation of the reactor in a shopping mall, not in a laboratory.

Prague, Metropole Zličín · 2023

What we wanted to find out

Whether the reactor would keep running on its own, among people, with no laboratory behind it. And what happens to the culture when we give it air from a building instead of a CO₂ cylinder.

What we learned

Limited by supply. An average of 20 m³ of air an hour at an average concentration of 650 ppm flowed through the reactor. That corresponds to a flux of roughly 0.57 kg CO₂ a day and about 130 kg for the whole pilot.1 This flux is an upper bound: regardless of the state of the culture, no more carbon can be fixed than passes through the reactor. The measurement therefore does not characterise the biology but the sizing of the gas path. The conclusion for the next generation: raise the inlet concentration - with a concentrator ahead of aeration, or by connecting to a source where CO₂ is orders of magnitude more concentrated.

Transfer between phases. Even under this ceiling, what matters is how much of the CO₂ moves from the bubble into the medium before the bubble rises to the surface. The transfer rate increases with interfacial area and with residence time. That is why later work focuses on making the bubbles smaller and lengthening their path.

Equipment versus culture. Control, aeration, lighting and temperature regulation ran for 232 days with no operator intervention beyond scheduled servicing. The culture did not hold that stability: during the pilot it was renewed ten times and the medium composition was adjusted as we went. Equipment availability and cultivation stability are two separate tasks with their own failure modes, and the second is the harder one.

Closing the balance. The flow of 20 m³/h is an average inferred from a total, not a value from a calibrated flow meter, and we measured CO₂ only at the inlet.2 The share of carbon actually used therefore remains unknown. The difference between a value derived from dry biomass and a value measured on the gas is often considerable in the literature.3 Generation 04 therefore has calibrated flow measurement and CO₂ concentration at both the inlet and the outlet.

Energy balance of operation. Consumption was 1 166 kWh over 232 days, i.e. 5.0 kWh a day at an average power draw of 210 W. The electricity was supplied from wind sources with a guarantee of origin. At an emission factor of 11 g CO₂e/kWh for wind energy, the consumption corresponds to approximately 12.8 kg CO₂e. The estimated 40 kg of dry biomass harvested during the pilot binds stoichiometrically about 72 kg CO₂.4 Even at an inlet concentration of 650 ppm, therefore, operation bound several times more carbon than the emissions from powering it - and that is the condition we place on every deployment in DAC mode. Using the emission factor for Czech electricity generation for 2023, the same consumption would correspond to approximately 431 kg CO₂ - we give both figures because that is how they are calculated.5 The balance covers operating electricity only, not the manufacture of the equipment, preparation of the medium or processing of the biomass.

Operation in a public place. A shopping mall concourse is not a laboratory and places different demands on the equipment. The power supply is shared and subject to outages. The ambient temperature fluctuates with opening hours and the season, and temperature control has to respond to it. The service window is limited to hours when the mall is closed, and every intervention - taking a sample, replacing the culture, cleaning the tubes - happens in front of passers-by. Appearance thereby enters the operating plan: fouling of the tube walls is visible before it starts to affect light transmission, so the cleaning frequency is set by aesthetics, not by performance. On top of that come the noise of aeration in an enclosed space, the operator’s safety and hygiene requirements, and the physical accessibility of the equipment to visitors. These conditions determined the design of the stainless steel casing, the layout of service access points and the choice of servicing intervals.

What we would do differently today

A flow meter at the inlet and CO₂ at the outlet from day one. Without them the balance is a hole.

One culture, one medium, the whole time. Tune elsewhere.

No comparisons with trees. Nor with efficiency.

What we did not claim at the Metropole Zličín shopping mall - and will not claim

That Helena cleaned the air in the building. That it saved on heating. That it captured tonnes. Around the reactor the air was a little better and there was a little more oxygen - by how much, we did not measure at the time. Now we do.


Footnotes

  1. 111 360 m³ × 650 ppm × 1.84 kg/m³ ≈ 133 kg. Passed through, not captured. ↩︎

  2. 111 360 m³ / (232 days × 24 h) = 20.0 m³/h. The blower’s nominal rating was 24 m³/h - the actual figure is always lower. On Helena 04 we measure the flow. ↩︎

  3. Leflay, H., Pandhal, J., Brown, S. (2021). Direct measurements of CO₂ capture are essential to assess the technical and economic potential of algal-CCUS. Journal of CO₂ Utilization, 52, 101657. DOI 10.1016/j.jcou.2021.101657. The authors measured 17 % removal of CO₂ from the incoming stream at 5 % CO₂, whereas the traditional calculation from dry biomass gave around 1 % for the same conditions. ↩︎

  4. An estimate from the volume of harvests during the pilot, not a weighed balance. In dry biomass that corresponds to ~72 kg CO₂ (× 1.83 kg CO₂/kg dry biomass at ~50 % carbon). We do not use it as a figure for reactor performance - see the paragraph The pilot does not characterise performance. ↩︎

  5. Market-based: electricity from wind sources with a guarantee of origin. Emission factor 11 g CO₂e/kWh - harmonised median of 126 estimates, Dolan & Heath 2012, Journal of Industrial Ecology 16(S1), S136-S154 → 1 166 kWh × 0.011 = 12.8 kg CO₂e. Location-based: the emission factor for gross electricity generation in the Czech Republic for 2023 was 0.37 t CO₂/MWh (Ministry of Industry and Trade (MPO), Aggregate Energy Balance) → 431 kg CO₂. We give both because that is how they are calculated. ↩︎