Technology
Technology
What Helena is
A closed tubular system in which microalgae grow on medium and carbon dioxide - food to them, feedstock to us. Per square metre of footprint it captures orders of magnitude more CO₂ than a forest. Algae photosynthesise with the whole cell, build neither trunk nor roots, and in a reactor the culture is stacked upwards. At the Metropole Zličín shopping mall, at 650 ppm at the inlet, that came to roughly a hundredfold of a forest on the same area. At a CO₂ source the ceiling for a large reactor is around a tonne of CO₂ a year per square metre, i.e. roughly a thousandfold. The first we measured, the second we calculated - with a CO₂ supply and with electricity, which a forest does not need.1
The control system maintains light, aeration and temperature autonomously and measures pH, culture temperature, CO₂ at the inlet and outlet, oxygen and a range of other parameters every minute.2 A reactor with a volume of 760 litres draws about 240 W, including partial supplementary lighting.3
We work most often with the Chlorella vulgaris strain from the Culture Collection of Autotrophic Organisms, Třeboň.4 We are already developing the fifth generation of the reactor and have 232 days of operation in a public place behind us.5 We collaborate on development with the Czech Academy of Sciences and are members of the European Algae Biomass Association.6
Reactor 04
Volume Eight tubes 250 mm in diameter and 2 000 mm long give 785 litres geometrically, the working volume is 760 litres. The previous generation had the same number of tubes, 192 mm in diameter and 1 800 mm long, i.e. 417 litres - between 03 and 04 the volume almost doubled. The footprint is 1 m² and generation 04 weighs around 900 kg when filled.
Aeration Air - or CO₂ straight from a source - bubbles through the culture in the tubes. So far the only documented figure is the blower from the Metropole Zličín shopping mall: nominal 24 m³/h, 20.0 m³/h inferred from operation - the actual figure is always lower.
Light The reactor uses daylight and the LEDs only make up the difference when there is not enough of it. Not by the clock, but by what the culture needs at that moment.
Sensors The CO₂ sensors are NDIR, calibrated with nitrogen 5.0, corrected per unit, with an accuracy of ±2 % at the reactor’s working point. Compared with operation at the Metropole Zličín shopping mall, generation 04 adds two things on which the whole balance rests: calibrated flow measurement and CO₂ concentration at both the inlet and the outlet.
Harvest The biomass is either a product (feed, nutraceuticals, biostimulant), or the carbon in it is stabilised by pyrolysis into biochar and stays in solid form for hundreds of years, but that is no longer use of the carbon, it is its storage. The figure of 2 g dry biomass/l/day used in the BICCAPS calculation is an input to the reasoning, not a measurement.
We provide a detailed technical specification on request.

Why concentration is decisive
A bubble passes through the reactor in a few seconds. At 420 ppm there is so little carbon dioxide in it that only a fraction dissolves in that time and the rest leaves at the surface. This is not a property of Helena - it is the weakest step in every photobioreactor, because gas transfer into liquid is slower than photosynthesis itself. What decides it is the interfacial area and the bubble’s residence time.
At the Metropole Zličín shopping mall we measured it in operation. An average of 20 m³ of air an hour at an average concentration of 650 ppm flowed through the reactor, which corresponds to a flux of roughly 0.57 kg CO₂ a day and about 130 kg for the whole pilot - it passed through, but it was not captured. That is an upper bound. Regardless of the state of the culture, no more carbon can be fixed than passes through the reactor. The pilot therefore does not characterise the biology but the sizing of the gas path. It is set out in detail in the case study Helena at the Metropole Zličín shopping mall.
Algae have their optimum in the single-digit percent range of CO₂: Chlorella grows best at 5 % and above 10 % growth is suppressed, whereas air holds 0.042 % - three orders of magnitude less.7 Everything that follows starts here. Two activities are running today with the Institute of Chemical Process Fundamentals of the Czech Academy of Sciences under the Technology Incubation project until 7/2027: a concentrator that raises the inlet concentration to 1 500 ppm and above, and bubbles smaller than 1 mm. The third route is connecting straight to a source, where CO₂ is orders of magnitude more concentrated. The fourth is BICCAPS - delivering carbon dissolved in the medium and skipping the gas step entirely.
Where Helena stands among capture methods
The other routes end with pure CO₂ that has to be compressed, transported and stored. Helena ends with biomass, and its durability depends on what we do with that biomass. Eight capture methods stand side by side on a separate page, each with the same three facts: where the CO₂ comes from, how long it stays stored and what the method leaves behind. Full comparison →
What Helena cannot do
It will not clean a building In the reactor’s immediate surroundings it improves the air and measures by how much - it will not clean a whole building. The oxygen difference between inlet and outlet is typically 20.7 % against 21.1 %, from operation at the Metropole Zličín shopping mall that works out at about 0.23 kg O₂ a day - as much as a quarter of a person breathes. That is not oxygen for a building and we do not claim it is.
It will not store carbon permanently Biomass on its own is a short cycle: on decomposition the carbon returns to the atmosphere. Durability comes only with pyrolysis into biochar, and that is a separate stage with its own balance, which we do not have quantified yet. For the biomass customer these are avoided emissions, i.e. the difference against the same product from a fossil input. It is neither removal of CO₂ from the atmosphere nor a carbon credit, and the quantification will come only from an LCA that is being prepared.
It cannot do without electricity A forest does not need it - and besides carbon it gives timber, biodiversity, retained water and a cooler landscape. A reactor will not replace that. Per square metre of footprint a reactor captures orders of magnitude more CO₂ than a forest. At the Metropole Zličín shopping mall, at 650 ppm at the inlet, that came to roughly a hundredfold of a forest on the same area. At a CO₂ source the ceiling for a large reactor is around a tonne of CO₂ a year per square metre, i.e. roughly a thousandfold. The first we measured, the second we calculated.1
It does not hold the culture as reliably as the equipment At the Metropole Zličín shopping mall the control system, aeration, lighting and temperature regulation ran for 232 days with no operator intervention beyond scheduled servicing. The culture did not hold that stability: during the pilot it was renewed ten times and the medium composition was adjusted as we went. Equipment availability and cultivation stability are two different tasks, and the second is the harder one.
Its balance is not closed At the Metropole Zličín shopping mall we measured CO₂ only at the inlet and inferred the flow from a total, not from a calibrated flow meter. The share of carbon actually used therefore remains unknown. Nor do we use the estimated ~40 kg of dry biomass as a figure for reactor performance - it is an estimate from the volume of harvests, not a weighed balance. That Helena cleaned the air in the building, saved on heating or captured tonnes - we have not claimed it and will not claim it.
It cannot yet do the alkaline route BICCAPS is an open problem. Unadapted Chlorella vulgaris is inhibited above about pH 9, at high pH phosphate precipitates and iron drops out, absorption from ambient air is slow without a catalyst, and clarifying the medium before it enters the column is the same unsolved step as harvesting.
Footnotes
-
We calculate per footprint, because both a forest and a reactor occupy floor area and the culture in a reactor is stacked upwards. Helena’s footprint is 1 m². Measured (Zličín, ambient air, 650 ppm): ~40 kg dry biomass over 232 days ≈ 315 g CO₂ a day ≈ 115 kg CO₂ per m² per year - an estimate from a pilot with an intermittent culture, not reactor performance. Calculated (at a CO₂ source): the ceiling for a large reactor is ~1 t CO₂ a year per 1 m² of footprint. It requires a concentrated input, at 650 ppm that much carbon does not pass through the reactor. Temperate forest: net sink of 3.7 t CO₂e per hectare per year, i.e. 0.37 kg per m² per year - average for 2001 to 2025 (World Resources Institute, Global Forest Review). Afforestation in the temperate zone can reach 2.6 to 27.5 t CO₂/ha/year (Brown et al. 1996 via FAO). Against the 0.37 figure, Zličín works out at ~310× and the ceiling at a source at ~2 700× - in the running text we keep the conservative „roughly a hundredfold“ and „roughly a thousandfold“. This holds with a CO₂ supply and with electricity, which a forest does not need. ↩︎ ↩︎2
-
NDIR sensors calibrated with nitrogen 5.0, corrected per unit, ±2 % at the reactor’s working point. ↩︎
-
Reactor 04, figure from the technical documentation. Cross-check from operation at the Metropole Zličín shopping mall: 1 166 kWh / 232 days = 5.03 kWh/day = 210 W average. Documentation and operation agree to within ten percent. ↩︎
-
Chlorella vulgaris CCALA 266, Culture Collection of Autotrophic Organisms, Třeboň. Spirulina (Limnospira) was also tested at the Metropole Zličín shopping mall. ↩︎
-
Helena 01 to 04 in operation, the fifth generation in development. Helena 04 at Metropole Zličín, 232 days, March to October 2023. We counted days, not enthusiasm. ↩︎
-
Institute of Chemical Process Fundamentals of the Czech Academy of Sciences, v. v. i. EABA = European Algae Biomass Association. ↩︎
-
Fermentation gas is almost pure CO₂ - three orders of magnitude more than in air (0.042 %). Algae have their optimum in the single-digit percent range: Chlorella grows best at 5 % CO₂. Above 10 % growth is suppressed (Leflay, Pandhal & Brown 2021, J. CO₂ Util. 52, 101657). ↩︎